国产精品人人妻人人爽麻豆-97色网-欧美一级在线免费观看-超碰97人人做人人爱可以下载-亚洲影视一区二区三区-综合亚洲桃色第一影院-深爱婷婷-亚洲免费在线观看视频-日韩精品午夜-91高潮大合集爽到抽搐-久久国产劲爆∧v内射-百度-久久精品午夜一区二区福利-亚洲女人的天堂www-日韩视频精品-3p视频在线观看

Chiral column of Xinhe es-ovm
ULTRON es OVM has a particle size of 5 μ m and a pore diameter of 120 μ M. the chiral stationary phase is ovalbumin (patent number of chiral stationary phase us: 6027648). Ovalbumin is chemically bonded to the surface of silica gel, which conforms to USP L57. ULTRON es-ovm column packing has a lot of chiral recognition sites, which makes the column suitable for the separation of enantiomers in a wide range, and can be used for trace analysis. It is a special chiral column for clopidogrel bisulfate, and water can be used as mobile phase. According to the national drug standard, es-ovm chromatographic column is used as a special column for the determination of L-amlodipine isomer of benzenesulfonic acid. It can also be used to analyze mixed drugs, pesticides and other organic compounds.
Online

ULTRON es OVM has a particle size of 5 μ m and a pore diameter of 120 μ M. the chiral stationary phase is ovalbumin (patent number of chiral stationary phase us: 6027648). Ovalbumin is chemically bonded to the surface of silica gel, which conforms to USP L57. ULTRON es-ovm column packing has a lot of chiral recognition sites, which makes the column suitable for the separation of enantiomers in a wide range, and can be used for trace analysis. It is a special chiral column for clopidogrel bisulfate, and water can be used as mobile phase. According to the national drug standard, es-ovm chromatographic column is used as a special column for the determination of L-amlodipine isomer of benzenesulfonic acid. It can also be used to analyze mixed drugs, pesticides and other organic compounds.


Product characteristics

1. The immutable proteins (viscidin) were used as ligands.

2. Demonstrate a wide range of chiral recognition capabilities.

3. There is no need to pretreat the sample for chiral resolution.

4. It can be used in reverse phase.

5. It can be used for microanalysis (ng grade).

6. Use clopidogrel bisulfate (USP) as the product for delivery inspection.

7. The delivery solvent used is 30% acetonitrile / water solution with low viscosity.



2.png


ES-OVM-05-1502Ultron ES-OVM 150 mm x 2.0 mm I.D. 5um waters type
ES-OVM-05-1546SHINWA Ultron ES-OVM 150 mm x 4.6 mm I.D. 5um waters type


ES-OVM說明書操作要點.pdf


Recommended spare parts
Related to recommend
Online WeChat Phone 010-59812370/1/2/3 Customer TOP
Message